How To Buy
EN

In the rapidly evolving landscape of industrial automation, the integration of Programmable Logic Controllers (PLCs) and communication protocols holds vital importance. The aim of this article is to provide information on how to use MODBUS Gateway in PLC programming, enabling a seamless

PLCs: The Central Control Point of Industrial Automation

PLCs are control-focused units commonly used in industrial enterprises, manufacturing facilities, and automation systems. They function as the central nervous system of a facility, coordinating processes like data collection, analysis, decision-making, and control, forming the foundation of industrial operations.

MODBUS Protocols: Fundamental Communication Information

Modbus is a communication protocol extensively used in industrial automation systems. It finds broad application in factory automation, the energy sector, transportation systems, and various other industrial domains.

Modbus typically allows a main device (such as a computer or a controller) to communicate with multiple devices (such as sensors, motors, actuators). The Modbus protocol typically relies on a client/server model. The client is a device requesting data or sending commands, while the server responds to these requests or processes the commands.

This protocol is generally used in two different physical communication modes: Modbus RTU (Remote Terminal Unit) and Modbus TCP/IP.

MODBUS TCP: Ethernet Data Transfer

MODBUS TCP is a variant of the MODBUS protocol that operates in high-speed communication Ethernet networks, utilizing the TCP/IP network protocol. Data packets are transported via TCP/IP and are commonly used in industrial networks.

MODBUS RTU: Serial Communication Technology

In contrast to MODBUS TCP, MODBUS RTU is designed for serial communication and is an ideal choice for applications where Ethernet connections might be challenging. Data is usually packaged over serial communication tools like RS-485 or RS-232 and transmitted between devices.

MODBUS Gateway: Bridging Different Protocols

The MODBUS Gateway is an important tool facilitating communication between different industrial devices. For instance, it acts as a bridge, enabling data exchange between Modbus TCP/IP and Modbus RTU, connecting different devices through correct connection points to establish seamless communication.

Application Strategies: Integration of MODBUS Gateway with PLCs

The integration of Modbus Gateway with PLCs involves steps such as selecting appropriate devices, establishing connections, determining configuration settings, and testing data exchange. These steps are crucial to facilitate communication between different devices and ensure successful integration.

MODBUS Gateway in Mikrodev PLCs:

Mikrodev control devices can be programmed to work simultaneously as Gateways among the supported protocols. One of the blocks facilitating this is the Modbus Gateway block.

The Modbus Gateway block can provide services in two directions as listed below.

Connecting the Master and Slave blocks is sufficient for the Gateway to start working. If a request comes from a different ID than the Modbus ID on the Slave block, the relevant request will be read through the Master block.

·      Sample Application:

 

In this example, the Modbus Gateway block is used to create a gateway for Modbus RTU Master block to access Modbus TCP Slave block. The output of the Modbus RTU Master block is connected to the “Efe” input of the Modbus Gateway block, and the output of the Modbus TCP Slave block is connected to the “Sla” input. Request packets received over Modbus RTU are converted into TCP packets and sent to the TCP network. The response received from the TCP network is then sent back to the Modbus RTU network.

 

Case Studies: Real-World Applications of MODBUS Gateway in PLC Programming

 

Energy monitoring systems used in areas such as buildings or industrial facilities help track and manage energy consumption. These systems often work in integration with various energy measurement devices, smart meters, or sensors. The use of different communication protocols by different devices can complicate data exchange. Here is where the use of MODBUS Gateway comes into play:

For instance, you have an energy meter using Modbus TCP/IP protocol integrated into an energy monitoring system in a building and a temperature sensor using a different serial communication protocol. You aim to integrate the data from these two devices into a central control system or monitoring panel.

In this scenario, the MODBUS Gateway takes data from the energy meter using Modbus TCP/IP and combines it with the data from the temperature sensor using a different protocol, creating usable data for reporting or analysis through a central control or monitoring system.

This way, the MODBUS Gateway facilitates data exchange between different protocols in energy monitoring systems, enabling the aggregation and analysis of energy consumption data. This, in turn, can assist in improving energy efficiency, reporting, and decision-making processes.

Conclusion:

In conclusion, the MODBUS Gateway facilitates efficient and reliable communication between different devices by enabling integration with PLCs, a cornerstone of industrial automation. This contributes to increasing the efficiency of industrial processes and aids in more effective management of systems.

 

 

Other Post
All Posts
Kayseray Energy Monitoring and Control SCADA System
Kayseray Energy Monitoring and Control SCADA System
Energy monitoring and control, catenary line monitoring and control and switch position information of more than 20 substations within Kayseray, a light rail public transportation system that started
Read More
Gaziantep City Water and Sewerage Administration (GASKI) Sludge Incineration Plant
Gaziantep City Water and Sewerage Administration (GASKI) Sludge Incineration Plant
Mikrodev PLC products were preferred in the follow-up and control of the processes of Türkiye's first sludge incineration plant in Gaziantep. The process is carried out at 850 to 1100 degrees Celsius.
Read More
AFAD Disaster And Emergency Management Presidency Shelter & Command Center Automation
AFAD Disaster And Emergency Management Presidency Shelter & Command Center Automation
Mikrodev MP211 Series PLC products and ViewPLUS SCADA software were used in the Shelter and Command Center Automation. In the shelter system, alarm monitoring, energy monitoring and HVAC system contro
Read More
TEI TUSAS Energy Management SCADA System
TEI TUSAS Energy Management SCADA System
In the energy management system, more than 50000 energy data are monitored and controlled over ViewPLUS SCADA software by using Mikrodev DCS and IoT protocol gateway products at more than 100 stations
Read More
Increasing Efficiency: Using MODBUS Gateway in PLC Programming
Increasing Efficiency: Using MODBUS Gateway in PLC Programming
In the rapidly evolving landscape of industrial automation, the integration of Programmable Logic Controllers (PLCs) and communication protocols holds vital importance. The aim of this article is to p
Read More
Understanding the Essence of Industrial Automation
Understanding the Essence of Industrial Automation
Understanding the Essence of Industrial Automation   In the dynamic landscape of modern industries, the concept of industrial automation has emerged as a fundamental driver of efficiency, prec
Read More
Tekirdag City Water and Sewerage Administration (TESKI) Water Distribution SCADA System
Tekirdag City Water and Sewerage Administration (TESKI) Water Distribution SCADA System
Mikrodev RTU300 series remote terminal unit products are used at more than 350 stations in the drinking water distribution system in Tekirdag, Türkiye. The data at each point is sent to the central SC
Read More
What Is RTU Device?
What Is RTU Device?
What Is RTU Device? RTUs (Remote Terminal Units) are important components used in industrial automation systems. These devices communicate with field devices (sensors, actuators, switches, etc.) and
Read More
What Is Modbus?
What Is Modbus?
What Is Modbus and What Is It Used For?Modbus is a communication protocol used in the industrial automation sector. It was developed by Modicon (now Schneider Electric) in 1979 primarily for com
Read More
What are the Differences Between PLC and RTU? 
What are the Differences Between PLC and RTU? 
In the world of industrial automation, PLC (Programmable Logic Control) and RTU (Remote Terminal Unit) are two substantial devices. They are both used to automate and monitor process control, however,
Read More
CATALOG