RTU and PLC products installed in more than 200 wells, warehouses and pumping centers throughout Trabzon are managed through the ViewPlus SCADA software in the TİSKİ Control Center.

  • Over 200 wells, warehouses and pump stations
  • Over 200 MP211 series PLC and RTU300 series RTU
  • 10000 data control via ViewPLUS SCADA
  • Hot stand by redundant SCADA
  • Data transmission to Viewplus SCADA via MODBUS and IEC 60870-5-104
  • Detection of water leaks, preventive or corrective actions
  • Electricity savings by using motors/pumps efficiently
  • Water quality control by monitoring parameters such as chlorine, PH meter, turbidity
  • Alarm tracking
  • Daily, monthly, annual reporting

 

Other Post
All Posts
OPC UA and MQTT in Industrial Communication: Integration in Brownfield Factories
OPC UA and MQTT in Industrial Communication: Integration in Brownfield Factories
OPC UA and MQTT: Definition and Fundamental Differences In the context of industrial communication, OPC UA (Open Platform Communications Unified Architecture) and MQTT (Message Queuing Telemetry Tran
Read More
MODBUS TCP Protocols and Applications in Mikrodev PLC Devices
MODBUS TCP Protocols and Applications in Mikrodev PLC Devices
In previous blog titled “What is PLC Programming?”, MODBUS PROTOCOL Blocks and MODBUS RTU MODBUS Master and MODBUS RTU Slave connection and programming in Mikrodev MP110 and MP211 PLC Series devices a
Read More
Georgian Oil & Gas Corporation (GOGC) Rustavi RMS System
Georgian Oil & Gas Corporation (GOGC) Rustavi RMS System
RTU300 series remote terminal unit products and MBS100 series MODBUS gateway product were used in the RMS system commissioned in Georgia. Energy data is monitored over the ViewPLUS SCADA system over M
Read More
SCADA and RTU Architecture for Water Distribution and Treatment Facilities
SCADA and RTU Architecture for Water Distribution and Treatment Facilities
The management, distribution, and wastewater treatment processes of water resources have evolved from manual controls to fully automated, intelligent systems. At the heart of this transformation are W
Read More
What are the Differences Between PLC and RTU? 
What are the Differences Between PLC and RTU? 
In the world of industrial automation, PLC (Programmable Logic Control) and RTU (Remote Terminal Unit) are two substantial devices. They are both used to automate and monitor process control, however,
Read More
What are Industrial Automation Products?
What are Industrial Automation Products?
What are Industrial Automation Products? Industrial automation involves using control systems, computers, and robots to automate an enterprise's production processes; and industrial automation produc
Read More
Comparison of MODBUS and IEC 60870-5-104 Communication Protocols
Comparison of MODBUS and IEC 60870-5-104 Communication Protocols
MODBUS and IEC 60870-5-104 are two different communication protocols widely used in industrial automation and control systems. They have different features and are used for different purposes. There a
Read More
PTP (IEEE 1588) vs NTP: Millisecond Precision Time Synchronization in Industrial Networks and SCADA
PTP (IEEE 1588) vs NTP: Millisecond Precision Time Synchronization in Industrial Networks and SCADA
How accurate is time alignment in industrial systems? Time synchronization means reliable data and accurate decisions in the field. An incorrect clock creates large gaps in fault analysis and quality
Read More
Ex4S Cyber Defense Simulation in the Energy Sector
Ex4S Cyber Defense Simulation in the Energy Sector
As Mikrodev, we provided Offensive Oriented Simulation infrastructure installations at the Ex4S Cyber Defense Simulation in the Energy Sector event, which was held for the first time this year at Repu
Read More
Alarm Management ISA-18.2: SCADA Alarms, Event Management, Priority, and Operator Effectiveness
Alarm Management ISA-18.2: SCADA Alarms, Event Management, Priority, and Operator Effectiveness
Imagine 3,000 alarms sounding in one shift. The operator tries to pick out the real danger within the noise, stress increases, and errors multiply. A critical pump stops a few minutes later, and the c
Read More
CATALOG